An example is shown on figure 7.1. A message of more than 64 characters is written into parallel port 0 (datain0[8:0]). The routing tables are loaded in order to route the message through several links configured in serial loop back mode and having it available on the parallel port 0 output.
Two pulses have been applied on fccreceived0 giving port 0 an emission credit of two flits (64 characters). When port 0 transmits characters, the signal sendata0 is high. When 64 characters have been sent, port 0 waits for another emission credit. The remainder of the message is emitted only when another pulse occurs on fccreceived0.
Port 0 pulses the signal sendfcc0, for one ckin clock cycle, each time 32 characters have been routed. This informs the emitter that it can send another flit to port 0.


 
Figure 7.1: Flow Control On link 0 